Monday, September 7, 2015

Magnetostrictive automatic tank gauge

Magnetostrictive automatic tank gauge various aspects of product advantages make magnetostrictive automatic tank gauge in many areas play a role in different measurement environments, the measurement method is not the same, the following brief magnetostrictive level Total service stations and oil depots in the application installation method.
When used to measure the level of horizontal tank, using top-mounted
Gas station horizontal tank installation method
Gas station horizontal tank installation method
underground fuel tank level gauge

working video:
KunLun Automatic Tank Gauge : https://www.youtube.com/watch?v=PZiS1JqVhpY
automatic tank gauge : https://www.youtube.com/watch?v=4rpMFKQ2H_k
automatic tank gauging system : https://www.youtube.com/watch?v=oj9l3OXplFQ



http://www.kunlunsensors.com/newspage.php?nid=162

Wednesday, August 19, 2015

automatic tank gauging system and fuel tank level sensor Working principle

automatic tank gauging system and fuel tank level sensor Working principle

In the measurement, the circuit first of the waveguide wire, the electric pulse, the electric pulse will produce a circular magnetic field, the magnetic field and the magnetic field of the magnetic field of the magnet, will produce a small distortion, this deformation along the waveguide wire to the two segment, when the signal pickup coil, the magnetic expansion effect will be sent out a small change in magnetic field, pick up the coil can detect this change in magnetic field. Since the distortion is a constant velocity moving along the guide wire, the time length of the time of the driving pulse is beginning to pick up the changing magnetic field.

oil tank gauge prices, fuel oil tank gauge for sale

Solution Introduction:

1.Magnetostrictive Probe + Console
2.Magnetostrictive Probe with Modbus protocol
3.Magnetostrictive Probe with 4-20ma

Flexible Magnetostrictive Probe Parameters:


Measuring range:0.3~25m
Measuring precision:±1mm
Resolution:0.1mm
Temperature measuring number:5
Temperature measuring range:-40~125°C
Temperature measuring precision:±0.5°C
Temperature measuring resolution:0.0625°C
Working temperature:-40~85°C
Medium density range:0.4~2.5g/cm3
Working pressure:0.05~10MPa
Protective Grade Explosion-proof label:IP67/Exia II CT6
Technics interface:G3/4" or M20×1.5
Electric interface:G1/2" or M20×1.5
Working voltage:DC12~24V
Working current:40mA
Communication protocol:RS485
Material of the probe Rod and floater:316L

oil tank gauge prices, fuel oil tank gauge for sale
oil tank gauge prices, fuel oil tank gauge for sale
oil tank gauge prices, fuel oil tank gauge for sale
oil tank gauge prices, fuel oil tank gauge for sale
oil tank gauge prices, fuel oil tank gauge for sale
oil tank gauge prices, fuel oil tank gauge for sale
KunLun automatic tank gauge working video :
automatic tank gauging system : https://www.youtube.com/watch?v=oj9l3OXplFQ
oil tank gauge : https://www.youtube.com/watch?v=w4rwLHABpjw
 

Tuesday, August 4, 2015

automatic tank gauging system consist of console and magnetostrictive probe

automatic tank gauging system consist of console and magnetostrictive probe
Console system from a magnetostrictive probe rod from a measured data drawn from the analysis results, and displayed in the page level and level of high and low temperatures, with high level low alarm, high water level low alarm, oil temperature of the high and low alarm function. At the same time, the analysis data is uploaded to the remote data center through the network port to store and analyze the data. The console also has the function of dynamic and static leakage and automatic / manual unloading.
 

automatic tank gauge system introduce

automatic tank gauge system introduce

As a system, the automatic tank gauge system is composed of the following parts: the magnetostrictive probe, the system control panel, the remote data center, the client network application software and so on. Which is the most important part of the liquid level meter and the system console, is the key to the product performance and technical parameters of the gas station liquid level meter system.
Magnetostrictive probe rod is according to the magnetostriction measurement principle of a magnetic telescopic level probe, which is characterized in that: it comprises a measuring rod), located in the measuring rod rear electronic warehouse, followed suit in measuring rod body with magnetic material ring float level and interface float, the measuring rod body is provided with a used for electrical / energy conversion machine waveguide wire and temperature sensor, electronic cabin with electronic measuring sensor. The utility model can be applied to the multi liquid level measurement. It in accordance with the requirements of the design of intrinsically safe explosion-proof design, and has high accuracy, good repeatability, convenient installation, non-contact measurement, environmental adaptability characteristics. It can be widely used in petroleum, chemical, water and electricity, pharmaceutical, food, beverage and other industries, the liquid tank of liquid level measurement.


http://www.kunlunsensors.com/newspage.php?nid=159

Wednesday, July 8, 2015

How to measure ground resistance fuel dispenser safest

How to measure ground resistance fuel dispenser safest
Fuel dispenser
In an explosive atmosphere, such as gas stations, oil, fuel tank and other equipment must be explosion-proof products. According JJF2-2003 "type anti-static grounding device detection norms", the main station to be tested following the grounding resistance and connection resistance facilities. Instrument testing must meet GB3836-2000 "explosive gas environment with electrical equipment" requirements.

Ex pump

Grounding system at the gas station, oil tank and auto fuel dispenser A ground electrode is connected to a ground electrode loading point C is a separate grounding. Find a separate ground electrode as an auxiliary ground electrode B (such as water pipe, etc.), according to the three-point method were measured with the Meter R1, R2 and R3.

Then find a fuel dispenser grounding mutually independent grounding, such as loading and unloading point grounding so on. With a test line connecting the two points, measured by the Meter readings RT. Where: RT is measured clamp resistance. RC for the loading and unloading point grounding resistors. The fuel dispenser grounding resistance: R = RT-RC

fuel dispenser
fuel dispenser manufacturer
fuel dispenser suppliers
fuel dispenser for sale
fuel dispenser
fuel dispenser for sale
fuel dispenser prices

Gas station in the pipeline designed to parties all sides need to pay attention

Gas station in the pipeline designed to parties all sides need to pay attention
Fuel dispenser
Process piping fixed station should adopt seamless. Buried pipe connections are to be welded. When there is severe corrosive effect on steel soil area buried pipeline, the choice of oil, soil corrosion resistance, static conductive composite pipe. In addition to these caveats, gas pipeline will also be required in the design of what?

1, Automatic Fuel Nozzle should adopt self-styled Automatic Nozzle, flow rate should not exceed 60L / min

2, when the tanker unloading unloading hose communicating, communicating oil and gas recovery hose, antistatic oil resistant hose should be used. Interconnecting hoses should not be less than the nominal diameter of 50 mm.

3, process piping at service stations should be laid underground, and can not pass through the station house and other built structures. When the oil pipeline and the trench, trenches and drains intersect, it should take appropriate measures to prevent leakage.

4, communicating with the tank inlet pipe, snorkel horizontal pipe, and oil and gas recovery tube should slope tank, its slope should be less than 2 ‰.

5, the oil pipeline system design pressure of not less than 0. 6MPa.

6, corrosion design process piping buried outside surface should be consistent with existing national standards "steel pipeline and storage tank corrosion control engineering design specification" of the relevant provisions of SY 0007, and should be used to strengthen the level of not less than the corrosion protection layer insulation.


fuel dispenser
fuel dispensers for sale
fuel dispenser manufacturers
fuel dispenser prices
fuel dispenser suppliers
automatic tank gauge

Gas station process piping design requirements?

Gas station process piping design process, which should be noted
Fuel dispenser
Gas station process piping design requirements?


1, must be enclosed unloading tanker unloading mode.

2, steam tanker unloading and offloading of oil and gas recovery system should be adopted.

3. When using unloading of oil and gas recovery system should meet the following requirements:
oil and gas recovery pipe interface l) tanker on manual valves should be installed;
2) The user interface of the enclosed unloading pipe joints should be located quickly and boring cover. It should be in the station vapor recovery pipe interface before
3) offloading pipe joints at service stations, oil and gas recovery pipe joints should be located above ground;
4) the tank level gauge should be set with high level alarm functions.

4, fuel dispenser shall not be located in the room.

5, supporting refueling stations should adopt the process tank submersible pump installed a pump for multi-machine (gun) of.

6, when using self-priming fuel dispenser, each fuel dispenser fuel varieties should be set individually into the pipeline.


fuel dispensers for sale
fuel dispenser manufacturers
fuel dispenser prices
fuel dispenser suppliers
automatic tank gauge

When the fuel dispenser vane pump fails, how should we respond?

Fuel dispenser
When the vane pump fuel dispenser is faulty, may cause Automatic Nozzle not out of oil, then how should we respond?

It can be divided into the following situations:

mechanical diesel fuel dispenser

① vane pump relief valve can not be closed. Due to a foreign body (broken shrapnel, etc.) stuck in between the relief valve spool and valve seat, caused by the oil pump is always done in the loop and can not flow, maintenance should remove the valve, remove the valve seat foreign body;

② Because the pump with the rotor blades and the shrapnel long do high-speed operation, will wear due to fatigue, fracture, leading to vent vane pump increases, even when serious loss of pumping action, the pump should be clear debris and repair the damaged blade , shrapnel, re-install the new replacement;

③fuel dispenser vane pumps and oil separators pad bonding surface of pump breakdown or anti-loaded, can also cause the vane pump high-pressure chamber communicates with the low pressure chamber, resulting in the loss of the vane pump oil discharge function;

④ vane pump rotor and the rotor shaft loose, causing the shaft idle, this time in need of replacement repair rotor or vane pump.

fuel dispensers for sale
fuel dispenser manufacturers
fuel dispenser prices
fuel dispenser suppliers
automatic tank gauge

Automatic Nozzle fuel dispenser will not appear out of the oil causes and solutions are there?

Automatic Nozzle fuel dispenser will not appear out of the oil causes and solutions are there?

fuel dispenser boot normally, but no oil Automatic Fuel Nozzle, may reverse the motor or transmission belt is loose, broken. If this is the reason, then we can properly adjust power phase sequence, adjust or replace the belt tensioner wheel can be. If oil and gas separator fails, then you score following cases were analyzed:


fuel dispenser filters (including conical strainer) is clogged serious. The filter should be cleaned to remove debris;

② oil separator valve stuck untapped oil caused no oil fuel dispenser. Maintenance should remove the valve, reassembly after clearing the debris, so that it can, the next move freely;

③ small oil separator float into the oil or off, can not form a high pressure cavity pressure, no oil will result in fuel dispenser;

④ oil separator pressure pad cover damage caused by high-pressure chamber communicating with the pressure chamber, resulting in high pressure cavity do not form a high-pressure fuel dispenser leaving no oil.

⑤ oil and gas man separator filter pads or spring seat damaged. Replace damaged seal.



fuel dispenser
fuel dispensers for sale
fuel dispenser manufacturers
fuel dispenser prices
fuel dispenser suppliers
automatic tank gauge

Thursday, June 25, 2015

The mechanical tank gauging system maintenance problems

The mechanical tank gauging system maintenance problems

Because of budget constraints, gas station management system , some factories continue to suffer because the communication constraints and low performance of mechanical storage tank liquid level meter and cause maintenance problems. Now the intelligent wireless technology, you need not automation system ( automated fuel management system )of radar based on Raptor tank for long distance signal line can be installed new. This will save materials, reduce the labor cost and the engineering design and project fundamentally execution time.   automatic tank gauge tank gauging system ATG system fuel tank level gauge oil tank gauge Fuel tank gauge

The tank gauging system automatic management

The tank gauging system automatic management

Emerson's smart wireless technology without ditch and bridge long wiring can save material, oil tank monitoring system ,reduce artificial cost and shorten the engineering design and project execution time. Austen farm state of Texas using the Emerson wireless technology, makes the automation management become more convenient, storage tank calibration methods and the cost is lower. Emerson will Rosemount? Ross Monte Raptor storage tank liquid level meter and smart wireless technology integrated connecting storage tank farm and the control room through the wireless way, can reduce the system up to 50% of the installation cost, automated fuel management system and also can reduce the implementation time of up to 60%, greatly reducing the expansion of storage tank farm automation required budget. automatic tank gauging system fuel tank level gauge Fuel Tank Monitoring System oil tank level gauge Fuel tank gauge tank gauging system

Design of vehicle fuel tank monitoring system based on remote communication

Design of vehicle fuel tank monitoring system based on remote communication

The monitoring device of automobile oil tank is based on the embedded computer technology and communication technology, and the speed measurement and measurement method of the quantity of the vehicle fuel tank with the modern control theory. Oil tank monitoring system, piecewise linear function to obtain the voltage change and the amount of oil amount of oil and fuel sensor voltage by the change of change curve simulation, the system can according to user needs to set the sampling time and voltage sampling timing oil sensor values, through the function calculation corresponding to the amount of oil values. At the same time, keep the previous sampling value, automatic fuel management system to judge the speed of the change of oil consumption, and realize the automatic detection of oil quantity of the fuel tank and the abnormal working state. automatic tank gauges oil tank level indicator fuel tank level sensor oil tank level sensor automatic tank gauging system fuel tank level gauge oil tank gauge oil tank level gauge

Tank gauging system

Tank gauging system

Measurement accuracy is a key factor in the measurement of stock, but the accuracy is just one aspect, the metering tank gas station management system, general requirements for tank gauging instrument to consider: safety, accuracy and repeatability, compatibility, friendly, easy to operate, capable of independent operation, easy to maintain and expand the operation reliability and validity. Additional requirements for tank automatic metering fuel management system: online diagnosis, for the output measurement, can be seamlessly integrated with the host system and the existing DCS, scalable, service and spare parts, satisfied with the price, supplier quality control program. automatic tank gauging system fuel tank level indicator oil tank level monitor digital oil tank gauge oil tank level gauge fuel tank level sensor tank gauging system

Oil tank monitoring system from kunlun

Oil tank monitoring system from kunlun

In the tank automation system, the overall configuration of the explosion-proof industrial, mechanical parts and electrical control part is currently the most advanced control technology, is to ensure that the correct speed, but also in line with access to oil and liquid height modification process synchronization. The main component of the horizontal ruler: Qingdao GUI level gauge itself is a professional production of tank capacity automatic calibration tank calibration software equipped with liquid level meter is adopted to select the best way to make liquid level meter resolution of 1mm, + 0.25 mm accuracy. At the same time, to ensure access to the oil level fluctuation in the minimization, based on the original product to add a tubular sheath, check the multi-channel data acquisition, real-time level, to ensure consistency shows the actual level. The user's water tank capacity correction process, such as the level of the fault of the water level gauge, Guizhou and the technology will provide a quick, timely service, and to protect the latter's products spare parts supply. The main components are: the flow rate is 0.2%, the flow rate is as high as 180L / min, 30 cubic meters in less than three hours to measure the entire calibration process safe, fast and accurate. At the same time, the flow meter calibration parameters can be adjusted through the control of the instrument, the accuracy of the flow meter adjusted to eight one zero per cent, to help users regularly self calibration automatic tank gauges diesel fuel tank level gauge oil tank float gauge oil tank alarm automatic tank gauging system fuel tank level sensor automatic tank gauge automatic tank gauge

Thursday, April 16, 2015

oil level monitor Indonesia

Typical system tank gauging system
The openness of the tank gauging system better, the smart wireless technology, has good scalability. Not only can be easily installed on existing equipment, also support the future always add or replace equipment. The use of a full range of tank liquid level meter assembly, including the high accuracy radar level use automatic configuration, two wire bus tank automation system technology, improved inventory management, the whole factory loss control, anti overflow tank protection and achieve efficient maintenance. The use of a full range of tank liquid tank gauging system level meter assembly, including the high accuracy radar level use automatic configuration, two wire bus technology, improved inventory management, the whole factory loss control, anti overflow tank protection and achieve station management system efficient maintenance. The trade connection authentication, applicable to most tanks, including the fixed roof tank gauging system, floating roof tanks and tank. A wide range of applications, from light to heavy products can be applied. Radar level condensate from the low design concept electronic diesel fuel pump based on application, in the world has more than 100000 Taiwan, and successfully installed for measuring from gas to liquid products of various heavy crude oil and bitumen.

oil level monitor Indonesia


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor

fuel tank level sensor Indonesia

Analysis of oil tank monitoring system requirements
Design of oil tank monitoring system, first determine the system design objectives and functional requirements, feasibility analysis from technical and economic point of view, then the scheme selection and design, considering the structure of hardware circuit is reasonable, cost-effective, to explore the functional framework PC oil tank monitoring system, the data structure and other details, then the detailed design and debugging, finally completed the design task. In the early stages of design, the main consideration of the following factors:
(1) reliability. Oil tank monitoring system operation is safe and reliable, stable performance, can be long-term continuous fuel dispensing equipment working in harsh environment.
(2) general. In the design, should fully consider the application object in common, the oil tank monitoring system has strong versatility, can be popularized in oil depot.
(3) compatibility. Oil tank monitoring system should be able to carry on different types of sensors, can measure various parameters.
(4) economy. tank level gauge system cost, high performance price ratio.
(5) the operation and maintenance convenience. In the aspect of software requirements, friendly man-machine interface, easy to operate; the hardware requirements, convenient maintenance and repair. Parameters of tank area set and modify: setting tank number, label setting, communication parameters, tank partition management definition.

fuel tank level sensor Indonesia

automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor

oil tank alarm Indonesia

General requirements for tank gauging syste
Metering tank is still large reserves of liquid in the tank to measure the generic product. It can be used to measure the stock, which measured the total product in the tank level gauge system can also be used to turn the output measure, that is, as product marketing and tax basis. The main two methods: measurement based on volume and quality. Tank gauging system based on volume, the stock of measurement achieved by measuring the level and temperature. In the gas station management system based on quality, the stock is measured using a liquid measuring hydrostatic liquid column made??. In turn inventory control measure or lose, no matter what method, the reliability and accuracy of measuring instruments is very important. Accuracy of measurement is a key factor in the stock measured, but accuracy is only one aspect of diesel transfer pump tank gauging systems need to consider the general requirements: security, accuracy and repeatability, reliability and validity, compatibility operation , friendly and easy to operate, the ability to operate independently, easy to maintain, scalable. Additional requirements tank gauging systems: online diagnostics can be used to measure the output switch can be seamlessly integrated with the host system and the existing DCS, scalable, service and spare parts, satisfactory price, supplier quality control procedures.
oil tank alarm Indonesia


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor

oil tank level sensor Indonesia

Fuel tank level gauge is a intelligent system apply to modern gas station management, tank level measurement is composed of level probe, console and management software. Oil tank monitoring system also can reflect the oil level, water level, temperature, and inventory information, play the role of environmental safety monitoring.
oil tank level sensor Indonesia


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor

fuel level indicator Indonesia

KunLun tank gauging system is through accurate measurement of fuel tank level sensor, oil tank level indicator, average temperature and other data in order to effectively manage inventory and shift the gas station business.

fuel level indicator Indonesia


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor

oil tank level indicator Indonesia

KunLun diesel tank level gauge can detect liquid level and temperature, automatic tank gauge systems has the advantages of both multi-function and long life. And electronic oil tank gauge had been choosed as the preferred products by petrochemical enterprises at home and abroad.
oil tank level indicator Indonesia


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor

tank level measurement Indonesia

Is the system of measuring performance verification through quantity and stability of measurement standard for comparison manner, to confirm its overall system uncertainty.Through theoretical calculation and calibration laboratory, automatic tank gauge systems confirm the automatic tank gauge systems is better than 0.05%, the overall uncertainty can conduct the accuracy level of 0.3% of fuel tankers of metrological verification, and its structure and the control performance is completely accord with the actual work needs.The electronic oil tank gauge can play a major role in the field of fuel tankers calibration, effectively reduce the staff labor intensity, improve work efficiency.

tank level measurement Indonesia



automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor

tank level controller Indonesia

Diesel tank level gauge to satisfy the use of outdoor work, on the whole electronic oil tank gauge the corresponding explosion-proof insulation measures are taken, and designed a light and handy data collector as a signal at the receiving end, the reasonable collocation of this data collector through hardware and software design, do the humanized menu, practical function.Main metering performance test of the system through the laboratory calibration and comparison method, a higher level through laboratory measurement standard quantity traceability, its length, temperature and capacity to get a reliable calibration measurement indicators.

tank level controller Indonesia


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor

mechanical fuel level gauge Indonesia

In magnetostrictive liquid level meter liquid level magnetic feet two platinum resistance thermometer, can accurately measuring oil gun during fuel outlet temperature and the temperature of the oil in the standard metal gauge, its design index value of 0.1 degrees Celsius, higher than 0.2 degrees Celsius degree value requirements.Through signals transmission lines to liquid level and temperature signal output to the use of single chip microcomputer principle in the design of the data collector to complete liquid level height and temperature signal acquisition and calculation, tank gauging system the data terminal power supply convenient way, used the 12864 LCD module for display, and design the manipulation of the human interface with PC communication function, tank gauging system appearance is small and light, suitable for outdoor use in northeast China, the great convenience for the practical work oil tank level indicator.

mechanical fuel level gauge Indonesia


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor

Fuel tank gauge Indonesia

Tank gauging system is mainly composed of standard metal basket, magnetostrictive liquid level sensor, platinum resistance thermometer, data collector and so on, the system maximum allowable error less than 0.05%.By calculation we choose 100 l second-class standard metal gauge as the primary standard, its maximum allowable error is better than 0.025%, oil tank level indicator far more than the fuel tank level sensor verification of fuel tankers standard 0.05% of the maximum permissible error requirement, at the same time, the structure design and manufacture of fully meets the requirement of verification of fuel tankers standard.Magnetostrictive liquid level sensor is made using magnetostrictive principle of high precision, long linear range and absolute position measurement of liquid level sensor and its circuit is simple, with flame-proof performance and good environmental adaptability, reliability and stability, and adopts non-contact measurement method, solves the caused by friction, abrasion and other low service life, its fuel tank level sensor design resolution can reach 0.1 mm.Temperature measurement using inline.

Fuel tank gauge Indonesia


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor

oil tank level gauge Indonesia

The tank level measurement through the data collector to modify the sensor output value and calculation, mainly through laboratory calibration for liquid level, temperature, standard metal gauge zero calibration parameters such as capacity, measuring neck dividing value for verification and correction, to ensure the accuracy degree of each sensor and the calculation results accurate and reliable.The system on the structure and signal processing design concept can also be further ascension.Based on the fuel.
Tanker using sensors by oil tank monitoring system of processing and modification, heat preservation performance enhancement, fuel tank level gaugeupgrade to bubble function improvement, data collector, tank level measurement can further the structure of the system and the main measuring performance is perfect, form a complete outline of technical solutions and product evaluation, then the evaluation of new product type, make real products into market, the system enables the project has been applied in the field of fuel tankers verification, play a major role, reduce the labor intensity of workers, improve the work efficiency.

oil tank level gauge Indonesia


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor

Fuel Tank Monitoring System Indonesia

Fuel tank level gauge measuring performance test mainly through laboratory calibration and comparison method, a higher level through laboratory measurement standard quantity traceability, its length, temperature, volume measurement index is a reliable calibration, all its measurement indexes can be traced back to the national standards of measurement, to ensure that the use of various measurement instrument has reliable quantity traceability system.Is the system of measuring performance verification through quantity and stability of measurement standard.
Value than manner, in accordance with the relevant procedure for fuel gas automatic verification system for comparison test, the results of data processing by En value to confirm, and the oil tank monitoring system is integrated the uncertainty evaluation of measurement results to judge whether it can meet the needs of practical work.

Fuel Tank Monitoring System Indonesia


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor

fuel tank level gauge Indonesia

To start with, the electric methods of computerized pipeline leakage techniques are quite distinct. Tests for mechanical leakage detectors might not be fully operated in computerized pipeline leakage programs, which means that every kind of leakage detectors has to be provided a unique examination packages. Second, lots of electrical systems are remotely monitored by consumers or perhaps the 3rd get together that's assigned in advance. According to recommendations, tank calibration program will set off alarm then certainly be seen through the centre of inspection and checking. Hence, coordination is necessary between both sides of remote checking. Alarm will be turned off given that the data of inspecting process was given out to authority. Third, when leakage detector is operating, electric powered system might require to show off the submerged pump. Differing kinds of electric systems have different applications to verify your situation of no leakage and make the pump return to standard. Specialists must execute special and special after-test programs for every type of electric systems.
fuel tank level gauge Indonesia



automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor

automatic tank gauging system Indonesia

It`s not precisely manufacturers` duty to create specifications of inspection. EPA has produced other directions of automatic casing leakage testers that operate in stress pipeline programs. The once-a-year exams of leakage detectors have to be in accordance with manufacturers` demands. Automated tank gauge technique can detect and examine pressure pipeline methods as well as sometimes can operate in the exact same way as computerized casing leakage testers do.

Once-a-year Exams For Computerized Casing Leakage Testers Are a minimum of Needed?

Yearly assessments for automated casing leakage testers usually are not precisely required. It`s value noting that EPA`s expectations are not one sided directions that has to be used to each condition. In distinction, it requires that every condition must attract up and have out at least one particular environmental approach that is in accordance together with the stringent federal performance specifications. Each and every state has the best to prepare more tests and inspections.

About tank calibration services of Automatic Pipeline Leakage Programs

It`s a prevailing craze for directors to feel the idea that leakage testers` yearly assessments should be in accordance with manufacturers` specifications and existing functioning exams of automatic pipeline leakage systems should be provided. And these current operating exams bring out many problems that need to be solved.


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor

Wednesday, April 15, 2015

automatic tank gauge Indonesia

automatic tank gauge system, known as ATG, is a gadget of inspecting oil quality loss, which can be capable of inspecting leakage price of 0.2 gallons for every hour from any portion in typical oil tanks. This idea which can be understood from slim sense relates to automated tank calibration system and also the dowsing rod that's put in in fuel tank calibration and can be used to inspect oil top quality and temperatures.

Nevertheless, current ATG is capable of numerous environmental monitorings in gas station, like groundwater monitoring and chassis monitoring of gas dispensers and so on. ATG may also give inventory info of every day storage management.

Who develops specifications of automatic tank gauge program?

Needs had been considered and instructions of system upkeep had been made by EPA in the year of 1988. All operators of UST method need to supply a leak detector or perhaps a mixture of various leak detectors to ensure that they could set up, check, run and maintain automatic tank gauge program according to manufacturers` instructions. This requirement applies to all types of leak detectors which includes detecting approaches of oil tanks, pipelines and groundwater wells.



automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor


automatic tank gauge
ATG system
fuel tank level gauge
Fuel Tank Monitoring System
oil tank level gauge
oil tank level sensor
fuel tank level sensor

Thursday, February 5, 2015

KunLun tank gauging system Debug

KunLun tank gauging system Debug

KunLun provides highly customizable automatic tank gauge solutions exceeding petroleum site owners fuel and compliance management needs. Today, KunLun is providing a one-of-a-kind automatic tank gauge with the most advanced fuel monitoring technology to over 60,000 tanks worldwide.

KunLun fuel tank level gauge Debug :

You should perform proper debugging before using the probe.

Connect probes to the console.

Input the fuel’s standard density and factor to the console.

Measure the fuel height and the water height practically and input the data of them to the
console.

The console deals with the data transmitted from the probe and then it displays the
product level、interface level and the temperature.

After discharging the fuel, you should measure the height of the fuel and water practically
again, then compare them with the displaying height, the error value between them
should be no more than ±0.5mm

Note: When the probe is working, don't open the
cover of the ElectronicHousing.
KunLun Tank Gauging System
KunLun Fuel Tank Level Gauge
video:

fuel tank gauge tank gauging system ATG system

KunLun fuel tank monitoring systems Electric Wiring

KunLun fuel tank monitoring systems Electric Wiring

automatic tank gauge
Automating compliance while optimizing operations. Problem solved.
KunLun is the top provider of fuel tank monitoring systems in the china. We do more than just automate your compliance and fuel monitoring; we protect your business investment.

Because KunLun is the China’s top supplier of automatic tank gauging system .

Electric Wiring
 You can insert a 4-cores shield cable (2 Twisted Pairs) on the wiring from control room to the tank area into a 3/4” galvanized steel pipe in order to meet the requirement of electric wiring.
 Adopt Explosion-proof Flexible Pipe on the probe cable, screw down the tie-in of the Explosion-proof Flexible Pipe and the seal bolt on the probe.
 Add a 6’’to4’’bushing and a copper nipple at the other end of the Explosion-proof Flexible Pipe which should be connected with the Explosion-proof Junction Box. The inner connection bolt of the Explosion-proof Junction Box should be wired reliably and the outer grounding terminal of the Explosion-proof Junction Box should also be grounded reliably. Flanges should be grounded reliably .
KunLun Fuel Tank Monitoring System
KunLun Fuel Tank Monitoring System
KunLun Fuel Tank Monitoring System

video:

automatic tank gauging system
automatic tank gauge
fuel tank monitoring system

Kunlun automatic tank gauge Note before installation

Kunlun automatic tank gauge Note before installation

Kunlun delivers smarter automatic tank gauge to help our customers with all of their fueling operations and environmental compliance needs.

Kunlun automatic tank gauge Note before installation:
You should use oil dip rod to inspect whether the real installation height of the tank is consistent with the length of the probe that we supply.

Open the box to check the accessory list in order to examine whether there is any transport failure.

Kunlun ATG system Installation:

Fetch the flange at the tank’s fuel hatches.

Insert the probe into the installation orifice of the installation flange.

Install the Ajustable fitting,O-ring seal,Flange,Product Float, Interface Float and the Nylon Stopper on the probe in turn, then lock the Snap Ring.

Insert the probe into the fuel hatches.

Raise the probe after it is put at the bottom of the tank, make sure that the distance between the end of the probe and the bottom of the tank is 2~10mm,prevent the probe from getting curving and screw down the probe locknut.

Install the installation flange closely.
KunLun ATG system
KunLun ATG system
KunLun ATG system

video:


fuel tank gauge automatic tank gauging system fuel tank monitoring system

ATG system Technical Parameters

KunLun Automatic Tank Gauge System are mainly used in underground oil tanks of petrol station, this system consists of console and magnetostrictive probe. Magnetostrictive probe is installed in oil tanks, real time measuring oil liquid level, volume, water level and temperature inside tanks, at the same time transmit all the datas to smart console which install in office wall in real time.

ATG system Technical Parameters:
Measuring range:0.3~4m(can customize according to user’s request)
Safety Barrier input voltage: DC12V/40mA
Communication protocol:RS485
Baud rate:2400BPS
Transfer distance: 1.5Km
Measuring accuracy:±1mm
Repetition: 0.3mm
Resolution:
0.1mm
Nominal working pressure: 0~0.6MPa 0~1.6MPa 0~2.5MPa
Working medium density:0.4~1.3g/cm3
The material of the probe and the Electronic housing: 316L stainless steel probe
The probe is used for exactly measuring tanks and it had been applied in the fields of gas
station, chemical industry, foodstuff and pharmacy.

KunLun ATG system
KunLun ATG system
KunLun ATG system

video:

fuel tank gauge
oil tank monitor
automatic tank gauging system

KunLun ATG system


KunLun automatic tank gauge is used for measuring product level and it provides high precision. The Magnetostrictive probe has advantages such as steadiness,reliability,long-life,finished frame and strong adaptability. It can be installed at the top of tanks and the tank doesn’t need to be cleaned. So KunLun ATG system also has advantages such as safety, convenience and fast installation.

KunLun Magnetostrictive Probe is designed based on magnetostrictive theory. The electronic parts of the probe produce a low-voltage electric current "inquiring" pulse, at the same time the pulse produces a magnetic field which travels downwards along the waveguide. Because there are a group of magnets which also produce a magnetic field inside the floater which is moving up and down with the change of the liquid level, there are two magnetic fields in the probe.

When two magnetic fields meet, the waveguide will twist and one wave will be produced, we call it the "returning" pulse. Then the electronic parts detect the cycle from producing the pulse of "inquiring" to receiving the pulse of "returning", i.e. the corresponding accurate change of liquid level. Installing temperature sensors inside the probe can make it detect and transfer the liquid temperature continuously at the same time.
KunLun ATG system
KunLun ATG system
KunLun ATG system
KunLun ATG system
KunLun ATG system

video:

fuel tank gauge
automatic tank gauging system
ATG system

Gas station ATG system

Gas station safety and environmental protection involves a number of factors, which basically showed offloading overflow, rupture of underground storage tanks, oil and gas volatilization, pipeline rupture, personal accident caused by static electricity and other aspects. As China's Administration of Work Safety, environmental protection department has intensified supervision, safety and environmental norms in terms of oil, the world's environmental agencies and oil Equipment Association and other departments have developed a number of stringent performance standards, without exception in these standards have advocated the use of automatic tank gauge.
ATG system with high precision and high stability of the measuring stations characteristics are widely used for inventory change and change monitoring tank tank. In China, CNPC, SINOPEC more than 70% of the petrol station Fuel Tank Monitoring System manufacturers choose magnetostrictive probe. As a tank monitoring system in the most basic part of the monitoring is just one of the main functions of the tank level gauge deposit, along with the development of all regions of the country for safety and environmental pollution stations increased awareness and implementation of environmental regulations, gas stations level gauge from the traditional inventory management to the gas station facility safety monitoring operating status change management tools.
 KunLun production automatic tank gauge can not only save time display tank information, data upload, the basic functions of remote query, inventory management and other outside. PEI standard reference asked the US and the American Petroleum Institute, Qingdao your instrument and level probes can be carried out on the tank 0.2 gallons / hour (0.76 l / h) of the static tank leak monitoring; at the same time also on the oil level is high, low implement sound and light warning, alarm function, according to user needs, providing indoor and outdoor dual alarm, played the role of double insurance, you can completely avoid spills phenomenon.
KunLun ATG system
KunLun ATG system
KunLun ATG system
KunLun ATG system

video:

fuel tank gauge
automatic tank gauging system
ATG system