| Power supply : | DC12V, 50mA |
| Precision : | ±0.5mm |
| Resolution of product level : | 0.01mm |
| Resolution of temperature : | 0.0625℃ |
| Resolution of water level : | 0.01mm |
| Temperature range : | -40℃~280℃; |
| Points of temperature measured : | 5 |
| Maximum communication : | 500m |
| Communication : | RS-485 |
| Mark of explosion proof : | ExiaⅡCT6 |
| Definition of power cable : | Brown – POWER DC12V Blue – RS-485A Purple – RS-485B Black – GND |
| Medium applicable : | Gasoline, kerosene, diesel, light oil, heavy oil ,alcohol mixture |
Applied liquid products
1. Gasoline
2. Diesel
3. Kerosene
4. Ethanol Gasoline
5. Bio Diesel
6. Water
7. Other approved light oil products
Data measured
1. Product level
2. Water level
3. Temperature
4. Product inventory
5. Empty capacity (Order capacity)
Features
1. Transfer probe data to console in real time, including product level, water level,tempature
2. 5 points temperature sensors offer precision measurement as the basis of temperature compensation and leak detection
3. Digital signal transmit have remarkable highlights than traditional analog signals,especially on high anti-interruption ability, enhance long distance communication as 500m, and higher security.
4. Leak detection ability support 0.38Liter/Hour, and 0.76Liter/Hour, static and dynamic leak detection connects with console. This programmable Leak Detection can be set detect by daily,weekly, monthly or annually.
1. Gasoline
2. Diesel
3. Kerosene
4. Ethanol Gasoline
5. Bio Diesel
6. Water
7. Other approved light oil products
Data measured
1. Product level
2. Water level
3. Temperature
4. Product inventory
5. Empty capacity (Order capacity)
Features
1. Transfer probe data to console in real time, including product level, water level,tempature
2. 5 points temperature sensors offer precision measurement as the basis of temperature compensation and leak detection
3. Digital signal transmit have remarkable highlights than traditional analog signals,especially on high anti-interruption ability, enhance long distance communication as 500m, and higher security.
4. Leak detection ability support 0.38Liter/Hour, and 0.76Liter/Hour, static and dynamic leak detection connects with console. This programmable Leak Detection can be set detect by daily,weekly, monthly or annually.
How to get the probe length?
Probe length = H0
Probe length = H0
The probe length means the length from the bottom to the top under the electronic part, please see the graph as follows: