Grounding clamps and cable
SC-L1 One SC-01 clamp with 10 ft. spiral cable & terminal plug
SC-L2 Two SC-01 clamps with 10 ft. spiral cable
SC-L3 One SC-01 clamp with 10 ft. spiral cable & 1’’ pipe clamp
SC-L4 One SC-01 clamp with 10 ft. spiral cable & 3/4’’ C clamp
SC-T1 One SC-01 clamp with stainless steel wire & terminal plug
SC-T2 Two SC-01 clamps with stainless steel wire
SC-T3 One SC-01 clamp with stainless steel wire & 1’’ pipe clamp
SC-T4 One SC-01 clamp with stainless steel wire & 3/4’’ C clamp
we are professional manufacturer of Grounding clamps and cable.
Grounding clamps and cable : http://www.kunlunequipment.com
Tuesday, September 6, 2016
grounding clamps for drums
KunLun Equipment offers a wide variety of grounding clamps, from cast aluminum and cast bronze hand clamps for drum, railcars and trucks to pipe and c-clamps to aviation grounding clamps and plugs.
grounding clamps for drums : http://www.kunlunequipment.com
Static Grounding Clamps Application
Static Grounding Clamps Application
FM approved per Approval Standard 6085
Introduction:
In order to discharge the electrostatic charge from various equipment, we offer a wide range of static grounding clamps with cables.
Features & Benefits:
※ Die-cast aluminum construction with two stainless steel points.
※ Strong springpressure allows the clamp to penetrate multiple layers of paint or corrosion build-up, so that the proper contact is made.
※ Suitable for grounding and bonding a wide range of containers, drums and machinery.
Thursday, June 2, 2016
Difference between Coriolis Mass Flow Meter and the Volumetric Flow Meters
Compared to this, For the Volumetric Flow Meters:
1. We could randomly say that all the other types of flow meters except the Coriolis mass flow meters belong to the Volumetric Flow Meters, including the Thermal Mass Flow Meters, Turbine Flow Meters, Electromagnetic Flow Meters, Vortex Flow Meters, Rotameters, etc.
2. The Volumetric Flow Meters will directly measure the "Volume " of the measured medium. The "Volume" of the medium WILL BE affected by the factors of temperature, pressure, density, viscosity, etc.
3. The measurement of the Volumetric Flow Meters WILL BE influenced by the factors of temperature, pressure, density, viscosity, etc. And the compensation calculation IS REQUIRED.
4. The accuracy of the Volumetric Flow Meters is said to be reached by ±0.5%, ±1%. While, the actual accuracy is hard to reach the promised level of accuracy. Because the accuracy will be influenced by factors of temperature, pressure, density, viscosity, etc.
Coriolis Mass Flow Meter video :https://www.youtube.com/watch?v=T1_JbaDsYt0
1. We could randomly say that all the other types of flow meters except the Coriolis mass flow meters belong to the Volumetric Flow Meters, including the Thermal Mass Flow Meters, Turbine Flow Meters, Electromagnetic Flow Meters, Vortex Flow Meters, Rotameters, etc.
2. The Volumetric Flow Meters will directly measure the "Volume " of the measured medium. The "Volume" of the medium WILL BE affected by the factors of temperature, pressure, density, viscosity, etc.
3. The measurement of the Volumetric Flow Meters WILL BE influenced by the factors of temperature, pressure, density, viscosity, etc. And the compensation calculation IS REQUIRED.
4. The accuracy of the Volumetric Flow Meters is said to be reached by ±0.5%, ±1%. While, the actual accuracy is hard to reach the promised level of accuracy. Because the accuracy will be influenced by factors of temperature, pressure, density, viscosity, etc.
Coriolis Mass Flow Meter video :https://www.youtube.com/watch?v=T1_JbaDsYt0
Why choosing the Coriolis Mass Flow Meters?
For the Coriolis Mass Flow meters:
1. The measuring principle of the Coriolis Mass Flow Meter is the Coriolis Force principle. The Coriolis mass flow meter will directly measure the "Mass " of the measured medium. The "Mass" of the medium will NOT be affected by the factors of temperature, pressure, density, viscosity, etc.
2. The measurement of the Coriolis Mass meters will NOT be influenced by the factors of temperature, pressure, density, viscosity, etc. And the compensation calculation is NOT required.
3. The accuracy of the Coriolis Mass Flow Meters is ±0.1%, ±0.15%, ±0.2% optional. The accuracy will NOT be influenced by the factors mentioned above.
Coriolis Mass Flow Meter video : https://www.youtube.com/watch?v=T1_JbaDsYt0
1. The measuring principle of the Coriolis Mass Flow Meter is the Coriolis Force principle. The Coriolis mass flow meter will directly measure the "Mass " of the measured medium. The "Mass" of the medium will NOT be affected by the factors of temperature, pressure, density, viscosity, etc.
2. The measurement of the Coriolis Mass meters will NOT be influenced by the factors of temperature, pressure, density, viscosity, etc. And the compensation calculation is NOT required.
3. The accuracy of the Coriolis Mass Flow Meters is ±0.1%, ±0.15%, ±0.2% optional. The accuracy will NOT be influenced by the factors mentioned above.
Coriolis Mass Flow Meter video : https://www.youtube.com/watch?v=T1_JbaDsYt0
Tuesday, February 23, 2016
Hydrogen,carbon monoxide,hydrogen sulfide,methane,propane gas detector;alarm;meter;monitor
Hydrogen,carbon monoxide,hydrogen sulfide,methane,propane gas detector;alarm;meter;monitor

Sensor type: Catalytic or electrochemical gas sensor
Gas sampling: Natural diffusion
Power supply: DC24V±25%
Power consumption: ≤3W
Working method: Continuous monitoring
Error rate: ≤±5%F.S.
Indication method: 4-digit LED light
Condition display: 3 LED lights indicate fault alarm, L-alarm level
alarm and H-alarm level
Operation: Infrared remote control
Response time: ≤30s (LEL) / ≤60s (toxic gas)
Working temperature: -40℃ ~ 70℃ (LEL) / -20℃ ~ 50℃ (toxic)
Working humidity: <93%RH
Explosion-proof: Ex dⅡCT6 Gb
Protection: IP65
Pressure Limit: 86-106kPa
Output signal: 4 to 20mA standard signal(RS485 output optional)
relay output
Install screw thread: G1/2"
Cable dimension: ≥1.5mm2×3
Transmit distance: ≤1000m
Dimensions and weight: l×b×h,mm 210×200×105 about 1000g
Hydrogen,carbon monoxide,hydrogen sulfide,methane,propane gas detector;alarm;meter;monitor
working video: https://www.youtube.com/watch?v=_N_PKkBLlAg
website: http://www.kunlunsensors.com/productpage.php?pid=55
Sensor type: Catalytic or electrochemical gas sensor
Gas sampling: Natural diffusion
Power supply: DC24V±25%
Power consumption: ≤3W
Working method: Continuous monitoring
Error rate: ≤±5%F.S.
Indication method: 4-digit LED light
Condition display: 3 LED lights indicate fault alarm, L-alarm level
alarm and H-alarm level
Operation: Infrared remote control
Response time: ≤30s (LEL) / ≤60s (toxic gas)
Working temperature: -40℃ ~ 70℃ (LEL) / -20℃ ~ 50℃ (toxic)
Working humidity: <93%RH
Explosion-proof: Ex dⅡCT6 Gb
Protection: IP65
Pressure Limit: 86-106kPa
Output signal: 4 to 20mA standard signal(RS485 output optional)
relay output
Install screw thread: G1/2"
Cable dimension: ≥1.5mm2×3
Transmit distance: ≤1000m
Dimensions and weight: l×b×h,mm 210×200×105 about 1000g
Hydrogen,carbon monoxide,hydrogen sulfide,methane,propane gas detector;alarm;meter;monitor
working video: https://www.youtube.com/watch?v=_N_PKkBLlAg
website: http://www.kunlunsensors.com/productpage.php?pid=55
Fixed Gas Detectors | Combustible Gas Detection Price | Gas Alarm Detector - KunLun Company
Fixed Gas Detectors | Combustible Gas Detection Price | Gas Alarm Detector - KunLun Company
Fixed Gas Detectors
Combustible Gas Detection Price
working video: https://www.youtube.com/watch?v=xXNTwPiGjoI
website: http://www.kunlunsensors.com/productpage.php?pid=55
Fixed Gas Detector
The instrument adopts advanced 16-bit microcontroller with extra low power consumption and quick processing speed. It is firm and durable with the anti-skid design of shell. It is widely used in petroleum, petrochemistry, chemical industry, gas, coal, metallurgy and power system; safety detection in municipal administration, communication and traffic tunnel construction; electronics and semiconductor industry and other places where toxic and harmful gases exist.
Combustible Gas Detection Price
working video: https://www.youtube.com/watch?v=xXNTwPiGjoI
website: http://www.kunlunsensors.com/productpage.php?pid=55
Combustible Gas Detector Alarm - Fixed Gas Detectors - KunLun Company
Combustible Gas Detector Alarm - Fixed Gas Detectors - KunLun Company
Fixed Gas Detectors
working video: https://www.youtube.com/watch?v=n_yxSe6e-Q4
website: http://www.kunlunsensors.com/productpage.php?pid=55
Fixed Gas Detector is widely used in such industries such as petroleum, chemical, natural gas, coal, metallurgy, electric power, municipal administration, telecom,tunnel construction,gas storage station, special plants and other places where flammable gases or toxic and harmful gases exist.
Combustible Gas Detector AlarmFixed Gas Detectors
working video: https://www.youtube.com/watch?v=n_yxSe6e-Q4
website: http://www.kunlunsensors.com/productpage.php?pid=55
Fuel Water Oil Leak Detection for SF Tank|Double Wall Tank,Interstitial Monitor
Fuel Water Oil Leak Detection for SF Tank|Double Wall Tank,Interstitial Monitor
Fuel Water Oil Leak Detection
Interstitial Monitor for Fuel Water Oil Leak Detection
Performance:
1. This sensor is equipped with fault self-checking function, free from artificial fault test;
2. This sensor is equipped with oil-water differentiation function, which can provide basis for judging leakage of inner tank or leakage of outer tank;
3. This sensor is equipped with flange, placed firmly and installed easily;
4. This sensor adopts RS485 communication and reduces wiring cost;
5. This sensor adopts oil resistant and corrosion resistant cable, which is durable in use.
Leak Detection Sensor Technical Parameters:
1. Response time<1S
2. Working voltage: +12~14VDC
3. Working current: 25~30mA
4. Working temperature: -40°C to +60°C
5. Precision of leakage liquid level detection: <3mm
6. Explosion-proof sign: ExiaIIBT4Ga
Interstitial Monitor for Fuel Water Oil Leak Detection
Leak Detection System for SF Tank|Double Wall Tank;Fuel Water Leak Detection,Interstitial Monitor
Leak Detection System for SF Tank|Double Wall Tank;Fuel Water Leak Detection,Interstitial Monitor
Product Features:
Safety: Explosion-proof ExiaIIBT4 issued by PCEC. The sensor structure is 304 stainless.
Sensitive: the instrument detect accuracy <3mm, response time <2s
Stability: frequency variation of piezoelectric transducer belong to physical attribute, without structure, light and other factors interference. It can adapt to the complex environment, and with great anti - interference performance.
Intelligent trouble diagnosis: alarm lamp will flash when anything goes wrong with sensor. Users can inform factory alarm lamp status so that technicians judge the faults and repair it.
Intelligent oil/water diagnosis: detecting water and oil between the two layers of double-deck tank,when there are leakage between the two layer of tank, the KL-TE Sensor will detect it.
Simple Installation:485 protocol bus standard, easy for installation.
Reserve switch output port, can realize interlocking control after connect with other equipments.
Leak Detection System for SF Tank|Double Wall Tank
Interstitial Monitor for Leak Detection System for SF Tank Double Wall Tank
Product Features:
Safety: Explosion-proof ExiaIIBT4 issued by PCEC. The sensor structure is 304 stainless.
Sensitive: the instrument detect accuracy <3mm, response time <2s
Stability: frequency variation of piezoelectric transducer belong to physical attribute, without structure, light and other factors interference. It can adapt to the complex environment, and with great anti - interference performance.
Intelligent trouble diagnosis: alarm lamp will flash when anything goes wrong with sensor. Users can inform factory alarm lamp status so that technicians judge the faults and repair it.
Intelligent oil/water diagnosis: detecting water and oil between the two layers of double-deck tank,when there are leakage between the two layer of tank, the KL-TE Sensor will detect it.
Simple Installation:485 protocol bus standard, easy for installation.
Reserve switch output port, can realize interlocking control after connect with other equipments.
Interstitial Monitor for Leak Detection System for SF Tank Double Wall Tank
Double Wall Fuel Tank Leak Detection | Interstitial Monitor - KunLun Company
Double Wall Fuel Tank Leak Detection | Interstitial Monitor - KunLun Company
Double Wall Tank Leak Detection System consist of KL-TX Console and KL-TE Leak Detection Sensor.
Interstitial Monitor for Double Wall Tanks Leak Detection.
Benefits:
Small size
Light weight
Easy to install
Reliable performance
Audible and visible alarms.
Automatic self check feature.
The magnetic sensor design provides for simple installation.
A switch is provided for audible or silent alarm mode.
6 sensors can be monitored at the same time.
Serial communication.
Double Wall Fuel Tank Leak Detection
Interstitial Monitor for Double Wall Fuel Tank Leak Detection
Double Wall Tank Leak Detection System consist of KL-TX Console and KL-TE Leak Detection Sensor.
Interstitial Monitor for Double Wall Tanks Leak Detection.
Benefits:
Small size
Light weight
Easy to install
Reliable performance
Audible and visible alarms.
Automatic self check feature.
The magnetic sensor design provides for simple installation.
A switch is provided for audible or silent alarm mode.
6 sensors can be monitored at the same time.
Serial communication.
Double Wall Fuel Tank Leak Detection
Interstitial Monitor for Double Wall Fuel Tank Leak Detection
Double Wall Tank Leak Detection, Fuel Oil Tank Leak Detection, Interstitial Monitor
Double Wall Tank Leak Detection, Fuel Oil Tank Leak Detection, Interstitial Monitor
Interstitial Monitor Description
It is used to detect water or oil leakage of double storage wall tanks.
Features & Benefits:
Audible and visible alarms.
Automatic self check feature.
The magnetic sensor design provides for simple installation.
A switch is provided for audible or silent alarm mode.
10 sensors can be monitored at the same time.
Serial communication.
Double Wall Tank Leak Detection
Interstitial Monitor for Double Wall Tank Leak Detection
working video : https://www.youtube.com/watch?v=AqSOGf97Tfk
website: http://www.kunlunsensors.com/productpage.php?pid=54
Interstitial Monitor Description
It is used to detect water or oil leakage of double storage wall tanks.
Features & Benefits:
Audible and visible alarms.
Automatic self check feature.
The magnetic sensor design provides for simple installation.
A switch is provided for audible or silent alarm mode.
10 sensors can be monitored at the same time.
Serial communication.
Double Wall Tank Leak Detection
Interstitial Monitor for Double Wall Tank Leak Detection
working video : https://www.youtube.com/watch?v=AqSOGf97Tfk
website: http://www.kunlunsensors.com/productpage.php?pid=54
Subscribe to:
Comments (Atom)